[060Dev Version] Simple Tutorial for Biological Oscillator Generator
The Bio-Oscillator Generator is a new multi-block power generation device added in 0.6.0, unlocked at the UHV tier. This device has a unique operating mechanism and control method different from traditional machines. This article mainly introduces a low-cost control strategy.
The English translation is incomplete
3 of 15 blocks have no English translation yet and are shown in the original language.
Machine translation
Parts of this page's English were produced automatically by the translation service.
1 Automated Display
1.1 Bio-Oscillator Electro-Stimulator Section
(1) Redstone Control:
(2) Redstone Timer:
Note: Just keep stretching (t).
(3) Redstone Repeater: 4 ticks
(4) Machine Control Unit
Note: Enable Invert
(5) Organization of sensor minimum and oscillating electrical stimulator electrical stimulation intensity
Organization | Organization Sensor Minimum | Electrical Stimulation Intensity |
|---|---|---|
1 Biological Myocardium Cluster | 489 | 15% |
2 Mutated Myocardium Cluster | 728 | 22% |
3 Dragon Myocardium Cluster | 1217 | 37% |
4 Modified Dragon Heart | 1958 | 59% |
5 Awakened Dragon Heart | 2772 | 88% |
Note: Max value of organized sensors can be increased, no inversion needed. Stimulators can be equipped with adjustable maintenance bays, processing time can be reduced.
1.2 Biological Oscillator Generator Section
(1) Boot-up process
① First, confirm if the operating control block level meets the organization's requirements;
② First, load the organization (1~64) and the corresponding level of connecting rods;
③ Confirm if the relevant chambers are loaded, if the stimulator's stimulation intensity is set, and if the sensor parameters are set (chambers related to the generator have a connecting rod chamber, input bus, input chamber, a sufficiently large power chamber, and an output chamber/output assembly);
④ Fill in 0.001~1M B of culture medium no less than what the organization requires to start power generation.
(2) Related Notes:
1-4 Nutrient Solution Empty Threshold can be set to 0. Awakening Dragon Heart Threshold can be set between 5%-10% or 0%. This depends on your personal preference. If you want to maintain continuous electric stimulation gain, choose the former. If you want to save nutrient solution, choose the latter.
Due to the current resource consumption of this generator being too expensive, the subsequent explanation and data reference sections will be updated after adjustments.
Items in this article
Comments
0No comments yet.
Your comment appears under your display name.